radtronics022004.jpg
{Copyright (C) 2007 Radtronics Pty. Ltd. All Rights Reserved}
radtronics022003.jpg
              DRM Series Wireless
            Radiation Area Monitoring
Rotem DRM Series Wireless Radiation Area Monitors
Features
Specifications
Ordering Information
Specification subject to change without notice 
Specification subject to change without notice
Models
DRM-1 with Dual GM Wide Range Detector (0.1µSv/h to 10Sv/h).
DRM-1D with higher sensitivity CsI(Tl) detector (0.01 µSv/h - 0.1 mSv/h)

The DRM series offers remote wireless Area Monitoring and is designed specifically to be used as a fixed monitor in varying dose rate fields.

The DRM-1 is configured with two very sensitive, auto switching GM tubes providing a linear response over 0.1µSv/h to 10Sv/h.  The DRM-1D is suited to low range applications and achieves higher sensitivity with a CsI(Tl) detector providing a linear response from 0.01 µSv/h to 0.1 mSv/h  The DRM series are wall-mounted, AC mains powered, with NiMH backup batteries. Data is transmitted by either 900 MHz FHSS, 2.4 GHz FHSS wireless or via hardwire (RS-232 or RS-485) to a Remote Monitoring System.

radtronics022002.jpg
radtronics004004.gif
Download data sheets:
DRM-1 (0.1 µSv/h - 10 Sv/h)
DRM-1D (0.01 µSv/h - 0.1 mSv/h)
radtronics022001.jpg

Measuring Range:

0.1. µSv/hr to 10Sv/hr (DRM-1)
 0.01 µSv/hr to 0.1 mSv/hr (DRM-1D)

Sensitivity:

0.3cps/mR/hr (137 Cs) (DRM-1)
6.8 cps/µR/h (137Cs) (DRM-1D)

Accuracy:

±10 % of reading within measuring range

Units:

µSv and µSv/hr

Power Source:

External AC Power backed up by two NiMH batteries

Temperature Range:

Operation: -10oC to +50oC (15oF to 122oF)

 

Storage: -20oC to +60oC (-5oF to 140oF)

Humidity Range:

40% to 95% RH (non condensing)

Case:

Blue anodized aluminum

Dimensions:

93mm W x 148mm L x 56mm H (3.7 " x 5.8 " x 2.2 ")

Weight:

680g (1.5 lbs)

Radio Frequencies:

900 MHz FHSS or 2.4 GHz FHSS

DRM-1

#4-0018

DRM-1D

#4-0019

 

OPTIONS
             

 

Remote Alarm/Display

4-0018-90

WRM2 Base Tranceiver

6-7010

WRM2Mesh Repeater  

6.7020

 

 

·   Output of dose rate and accumulated dose

·   Ruggedized construction, metal casing

·   User-selectable internal alarm threshold

·   Built-in RS-232/RS-485 programming and data connection.

·   Data transmission on 900 MHz FHSS or 2.4 GHz FHSS 

·   Output plug for Local Alarm Unit.

·   Calibration software available

·   Compatible with RMV software for PC data collection

·   Compatible with WRM2 Base Transceiver and WRM2 Software Package 

·   Dead time correction

·   Alarms for detector overflow, low battery and detector failure

·   Automatic self diagnostic routines

·   RADNET and CE compatible