radtronics011011.jpg
{Copyright (C) 2007 Radtronics Pty. Ltd. All Rights Reserved}
radtronics011010.jpg
   Interchangeable Probes for Rotem
       DA Series Radiation Monitors
External interchangeable radiation detectors for the DA Series
Specifications subject to change without notice

The flexibility of the Rotem RAM DA Series can be expanded with a choice of nine external interchangeable detectors suitable for alpha, beta, low or high-energy gamma and X-ray detection.

All detectors feature: 

§         Simple plug-in digital interface

§          Automatic detector identification

§         Individual detector calibration factor stored within probe

§          Automatic unit selection according to detector

§          Optional extended cable lengths

§         Automatic detector self-diagnostic routines

 

radtronics011009.jpg
radtronics011008.jpg
radtronics011007.jpg
radtronics011006.jpg
radtronics011005.jpg

Application:  Measurement of gamma radiation over a very wide range. Based on different types of energy compensated GM tubes.Extended hook-up cable of up to 100 meters can be used.

Measuring Range:

GM-40: 250 µSv/h to 10 Sv/h

GM-41: 50 µSv/h to 1 Sv/h

GM-42: 0.5 µSv/h to 10 mSv/h

Application:  Efficient surface monitoring

of alpha, beta and gamma

radiation contamination,

based on 1ľ” Pancake GM

tube.

Sensitivity(137Cs):

~350 cpm/µSv/h

(3500 cpm/mR/h)

Measuring Range:

0 to 42,000 cps

radtronics011004.jpg

Application:  Surface monitoring for Alpha contamination.

Based on Ionization chamber.

Very easy to maintain.

100 cm2 (15.5 sq. in.)

Surface Sensitivity:

530 cpm per Bq/cm2

Measuring Range:

0 to 50,000 cps 

Application:  Wide range gamma, x-ray and beta radiation measurement.

Based on 0.5 liter atmospheric

ionization chamber.

Uses special features and

advanced technology.

Measuring Range:

1.0 µSv/h to 250 mSv/h

radtronics011003.jpg

Application:  Gamma scintillation probe for improved x-ray and low

energy gamma radiation

detection,based on thin Nal 2”

diameter scintillator

(2” dia. X 0.04” thickness).

S.C.A. can be set within the

energy range, optimized for 125I

detection and/or other isotopes

Energy range: 10 to 80 keV

125I Surface sens. : 440 cpm/Bqcm2

Measuring range: 0 to 50,000 cps

radtronics011002.jpg
Application:  Scintillation probe for high energy gamma radiation

detection. Nal 2” x 2” diameter scintillator.Optional Single channel analyzer (SCA)

Surface Sensitivity (in contact):

131I: 320 cpm/Bq/cm2

99mTc: 315 cpm/Bq/cm2

Range: 0 to 50,000 cps

GM-40 Series
PA-100
PM-10
PM-11
IC-10
GM-10

Learn more…

radtronics011001.gif

Learn more…

radtronics011001.gif

Learn more…

radtronics011001.gif

Learn more…

radtronics011001.gif

Learn more…

radtronics011001.gif

Learn more…

Home
Links
Downloads
Contact
Survey & Contamination Monitors
Area Monitoring Systems
Electronic Dosimetry
LSC, Gamma & Luminescence
Scanners - TLC Plates, Gels & Blots
HPLC Radioactive Flow Detectors
Automated PET Chemistry Modules
Pre-Clinical Imaging Systems
Products